VLHI - APMonitor Option

Main.OptionVlhi History

Show minor edits - Show changes to markup

June 08, 2017, at 10:51 PM by 10.5.113.159 -
Changed line 13 from:

See also VDVL, VLACTION, VLHI

to:

See also VDVL, VLACTION, VLLO

June 08, 2017, at 10:51 PM by 10.5.113.159 -
Changed lines 5-6 from:
to:
Added lines 12-13:

See also VDVL, VLACTION, VLHI

June 01, 2017, at 06:40 AM by 45.56.3.173 -
Added lines 1-11:

(:title VLHI - APMonitor Option:) (:keywords VLHI, Optimization, Estimation, Option, Configure, Default, Description:) (:description Upper validity limit:)

 Type: Floating Point, Input
 Default Value: 1.0e20
 Description: Upper validity limit

VLHI is the upper validity limit for a measured value. Validity limits are one way to protect an application against bad measurements. This gross error detection relies on a combination of change values and absolute limits to determine when a measurement should be rejected. If VLHI is exceeded, the measured value is placed at VLHI or the maximum move allowed by VDVL when VLACTION=1. If VLACTION=0, there is no change in the measured value when a limit (VDVL, VLHI, VLLO) is exceeded.